Описание

Measurement of magnetic field strengths to military standards
Key Facts
  • Frequency range 5 Hz to 10 MHz
  • Built to MIL-STD-461A, 462D and 461E
  • Individually calibrated
  • Shielded twin-wire connection
  • Spacing plate 7 cm (MIL-STD-461/462, DEF STAN59-41) and 5 cm (VG standards)

Brief Description The shielded and individually calibrated Magnetic Field Pickup Coil HZ-10 allows magnetic field strengths in the frequency range from 20 Hz to 200 kHz to be measured in line with standards MIL-STD-461/462, DEF STAN59-41, GAM EG13 and VG95377 Part 13. It comes with a calibration certificate for the frequency range from 5 Hz to 10 MHz. The coil is covered by an aluminium shielding for high isolation and connected via a shielded twin-wire line to avoid measurement errors caused by galvanic surface currents induced in the shielding.''